{"id":12133,"date":"2016-01-05T16:26:02","date_gmt":"2016-01-05T15:26:02","guid":{"rendered":"https:\/\/www.emcombustion.es\/en\/quemadores-atex-para-zonas-con-clasificacion-antiexplosiva\/"},"modified":"2022-12-16T17:36:03","modified_gmt":"2022-12-16T16:36:03","slug":"atex-burners-for-areas-with-explosion-proof-classification","status":"publish","type":"post","link":"https:\/\/emcombustion.es\/en\/atex-burners-for-areas-with-explosion-proof-classification\/","title":{"rendered":"ATEX burners for areas with explosion-proof classification"},"content":{"rendered":"<p><a href=\"https:\/\/emcombustion.es\/en\/project\/repsol-refineria\/repsol_p01_01\/\" target=\"_blank\" rel=\"attachment wp-att-414 noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-414\" title=\"ATEX equipment | ATEX and NEC burners | E&amp;M Combustion\" src=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/05\/repsol_p01_01-225x300.jpg\" alt=\"ATEX equipment for explosion-proof rating | ATEX and NEC burners | E&amp;M Combustion\n\" width=\"225\" height=\"300\" srcset=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/05\/repsol_p01_01-225x300.jpg 225w, https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/05\/repsol_p01_01.jpg 450w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><strong>ATEX Burners<\/strong>. E&amp;M Combustion has developed in recent years special <strong><a href=\"https:\/\/emcombustion.es\/en\/industrial-burners-em-combustion\/\">industrial burners <\/a><\/strong>designs for installation in areas with explosion-proof rating, both for ATEX (Explosive Atmosphere ) and NEC.<!--more--><\/p>\n<p>This type of <strong>ATEX burners<\/strong>\u00a0is practically mandatory use in industries such as <strong><a href=\"https:\/\/en.wikipedia.org\/wiki\/Refinery\">refineries<\/a>, <a href=\"https:\/\/emcombustion.es\/en\/references-burners\/operating-sectors\/petrochemical-and-refinery-industrial-burners-generators-heaters\/\">petrochemical plants<\/a>, <a href=\"https:\/\/emcombustion.es\/en\/references-burners\/operating-sectors\/energy-generating-combustion-equipment\/\">power generation plants<\/a><\/strong> , etc.<\/p>\n<p>The specialization of E &amp; M Combustion in the design of this equipment makes us one of the most competitive companies in the market in ATEX burner , with great experience and guarantee for such fabrications.<\/p>\n<p>ATEX designs for burners incorporate the advantages of standard equipment , adding components and designs suitable for every application and concrete plant.<\/p>\n<ul>\n<li>Monoblock burners from 1000-25000 KW<\/li>\n<li>Duoblock burners from 1000-85000 KW<\/li>\n<\/ul>\n<h3><a href=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/06\/ATEX1_cmyk.jpg\" rel=\"attachment wp-att-1205\" data-rel=\"lightbox-gallery-VDEty5Xu\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><br \/>\n<\/a><a href=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/06\/ATEX1_cmyk.jpg\" target=\"_blank\" rel=\"attachment wp-att-1205 noopener noreferrer\" data-rel=\"lightbox-gallery-VDEty5Xu\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1205 size-medium\" title=\"ATEX burner EExd zone 2 | combined cycle plant in Latvia | Industrial burners | E&amp;M Combustion\" src=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/ATEX1_cmyk-300x245.jpg\" alt=\"ATEX burner EExd zone 2 | combined cycle plant in Latvia | Industrial burners | E&amp;M Combustion\" width=\"300\" height=\"245\" srcset=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/ATEX1_cmyk-300x245.jpg 300w, https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/ATEX1_cmyk.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><span style=\"color: #ff9900;\"><strong>ATEX Zone Definition<\/strong><\/span><\/h3>\n<p>ATEX is called a series of European directives governing hazardous and also regulate the measures to ensure security and prevent an explosion.<\/p>\n<p>Explosive atmospheres are given in terms of :<\/p>\n<p>a) Presence of fuel<br \/>\nb ) Existence of oxidant (oxygen )<br \/>\nc ) An energy source to initiate the reaction<\/p>\n<p>The equipments have a category depending on the level of protection provided. The Category 1 (very high protection) are installed in Zone 0, the one with constant explosive potential; the category 2 (high protection) in Zone 1, the one with potentially explosive atmosphere; and category 3 (normal protection) in Zone 2, one that is not normally explosive, but it is in short periods.<\/p>\n<p>These assumptions require either intrinsically safe or explosion proof increased safety.<\/p>\n<p><a href=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/06\/AtexHor01_cmyk.jpg\" rel=\"attachment wp-att-1206\" data-rel=\"lightbox-gallery-VDEty5Xu\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\">\u00a0<\/a><a href=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/06\/AtexHor01_cmyk.jpg\" target=\"_blank\" rel=\"attachment wp-att-1206 noopener noreferrer\" data-rel=\"lightbox-gallery-VDEty5Xu\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1206 size-medium\" title=\"ATEX burners | gas processing plant Pemex | Mexico | Industrial burners | E&amp;M Combustion\" src=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/AtexHor01_cmyk-300x221.jpg\" alt=\"ATEX burners | gas processing plant Pemex | Mexico | industrial burners | E&amp;M Combustion\" width=\"300\" height=\"221\" srcset=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/AtexHor01_cmyk-300x221.jpg 300w, https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/06\/AtexHor01_cmyk.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <a href=\"https:\/\/www.emcombustion.es\/wp-content\/uploads\/2014\/05\/NRC_p01_01.jpg\" target=\"_blank\" rel=\"attachment wp-att-424 noopener noreferrer\" data-rel=\"lightbox-gallery-VDEty5Xu\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-424 size-medium\" title=\"Burner for NEC zone | Baiji power station | Iraq | Industrial burners | E&amp;M Combustion\" src=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/05\/NRC_p01_01-300x199.jpg\" alt=\"Burner for NEC zone | Baiji power station | Iraq | Industrial burners | E&amp;M Combustion\" width=\"300\" height=\"199\" srcset=\"https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/05\/NRC_p01_01-300x199.jpg 300w, https:\/\/emcombustion.es\/wp-content\/uploads\/2014\/05\/NRC_p01_01.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h3><span style=\"color: #ff9900;\"><strong>Special features ATEX Burners<\/strong><\/span><\/h3>\n<p>Once the customer defines the type and characteristics ATEX burners Zone, <a href=\"https:\/\/emcombustion.es\/la-empresa-respuesta-tecnica-combustion-industrial\/\"><strong>E &amp; M Combustion\u00a0design\u00a0and\u00a0manufacture burners<\/strong><\/a>, so that the\u00a0equipments\u00a0made are appropriate.<\/p>\n<p>Although increasingly manufacturing ATEX and NEC equipment is more widespread, few companies are capable of manufacturing burners based on specific customer requirements with regard to the definition of hazardous areas.<\/p>\n<p>E &amp; M Combustion is a leading and competitive company in this area and it is able to manufacture customized equipment, in a relatively short time, considering the different possibilities offered by NEC and ATEX standards with attractive prices for the customer.<\/p>\n<p><strong><a href=\"https:\/\/www.emcombustion.es\/wp-content\/pdfs\/en\/ATEXZone_EMCNews_n02_En.pdf\">Solutions and equipment for ATEX Zone<\/a><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ATEX Burners. E&amp;M Combustion has developed in recent years special industrial burners designs for installation in areas with explosion-proof rating, both for ATEX (Explosive Atmosphere ) and NEC.<\/p>\n","protected":false},"author":4,"featured_media":12227,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[271,273],"tags":[338,125,336,318,1083,367,339,1076,307,650,337,151,1183,1084],"class_list":["post-12133","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energynews-en","category-technology","tag-atex-burners","tag-quemadores-en","tag-clasificacion-antiexplosiva-en","tag-em-combustion-en","tag-equipment-for-atex-zone","tag-explosion-proof-classification","tag-explosive-atmosphere","tag-hazardous-areas","tag-industrial-burners","tag-nec-burners","tag-quemadores-atex-en","tag-quemadores-industriales-en","tag-refinerias-en","tag-solutions-for-atex-zone"],"_links":{"self":[{"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/posts\/12133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/comments?post=12133"}],"version-history":[{"count":0,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/posts\/12133\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/media\/12227"}],"wp:attachment":[{"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/media?parent=12133"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/categories?post=12133"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/emcombustion.es\/en\/wp-json\/wp\/v2\/tags?post=12133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}